Newsletter Subscription
Enter your email and we will send you more information
Falko HW Inverter is the hydrosplit for wall installation. Thanks to its elegant aesthetics, the thickness of only 20 cm and the high efficiency exchange battery with tangential fan unit with very silent features, it can be installed in any environment. Equipped with a digital regulation system with infrared remote control as standard. Complete with white casing with transparent LCD display, condensation collection tray andfiltro
The FALKO HW series is designed for:
DIRECT WALL INSTALLATION | INSTALLATION WITH PREDISPOSITION BOX |
---|---|
![]() |
![]() |
Falko can be installed directly on the wall or using common built-in installation boxes for air conditioners (with internal height >10cm). The minimum dimensions are shown as in the figure:
To facilitate installation, the "Larger predisposition box for Ikaro and Falko" (code TGCL30) is available, with the following dimensions:
The 2-way kits (code TGCL12) or 3-way kits (code TGCL13) with electrothermal actuator (code SLTS04) can be installed in the predisposition box, sold as an accessory.
CODE |
DESCRIPTION |
L [mm] |
H [mm] |
P [mm] |
---|---|---|---|---|
THM03A |
HYDROSPLIT FALKO HI-WALL 350 HW INVERTER |
850 |
300 |
198 |
THM05A |
HYDROSPLIT FALKO HI-WALL 500 HW INVERTER |
850 |
300 |
198 |
THM07A |
HYDROSPLIT FALKO HI-WALL 700 HW INVERTER |
850 |
300 |
198 |
THM08A |
HYDROSPLIT FALKO HI-WALL 850 HW INVERTER |
970 |
315 |
235 |
THM10A |
HYDROSPLIT FALKO HI-WALL 1000 HW INVERTER |
970 |
315 |
235 |
Description |
|
FALKO HW 350 |
FALKO HW 500 |
FALKO HW 700 |
FALKO HW 850 |
FALKO HW 1000 | ||
---|---|---|---|---|---|---|---|---|
Code |
|
THM03A |
THM05A |
THM07A |
THM08 |
THM10A |
||
Total cooling capacity 7°C (1) |
W |
1’730 |
2’570 |
3’330 |
4’280 |
5’100 |
||
Sensible cooling capacity |
W |
1’418 |
2’107 |
2’730 |
3’509 |
4’181 |
||
Water flow rate |
l/min |
5 |
7,5 |
9,7 |
12,5 |
14,9 |
||
Pressure drop only Falko HW |
kPa |
10 |
20 |
39 |
25 |
33 |
||
Pressure drop 2 and 3-way valves KVs=1.7 |
kPa |
5 |
9 |
20 |
23 |
32 |
||
Heating power 45 °C (2) |
W |
2’198 |
3’265 |
4’230 |
5’437 |
6’478 |
||
Water flow rate |
l/min |
6,3 |
9,3 |
12 |
15,5 |
18,5 |
||
Falko HW pressure drop |
kPa |
15 |
33 |
57 |
38 |
52 |
||
Pressure drop 3-way valve KVs=1.7 |
kPa |
7 |
14 |
22 |
34 |
47 |
||
Air flow rate max. speed |
mc/h |
340 |
510 |
680 |
850 |
1020 |
||
Sound pressure vel. max. (*) |
dB (A) |
42 |
42 |
43 |
47 |
49 |
||
Sound pressure vel. Med. |
dB (A) |
39 |
39 |
40 |
43 |
43 |
||
Sound pressure vel. min. |
dB (A) |
36 |
36 |
37 |
40 |
40 |
||
Power supply-protection degree |
V/ph/Hz |
230/1+N/50----IP23 |
||||||
Max. power consumption vel. |
W |
27 |
31 |
46 |
52 |
65 |
||
Maximum current |
A |
0,15 |
0,18 |
0,25 |
0,29 |
0,36 |
||
Plumbing connections |
pollici |
Rc ½” |
||||||
Water content |
Litri |
0,5 |
0,9 |
1,2 |
1,5 |
1,9 |
||
Condensate drainage pipe |
mm |
DN 15 |
||||||
Maximum operating pressure |
MPa |
1,6 |
||||||
Empty weight |
Kg |
11,5 |
12 |
13 |
16 |
17 |
(1) Temp. Inlet water 7°, Δ T 5 °C, Temp. Ambient 27 °C RH 47% (UNI EN 1397 :2015)
(2) Temp. Inlet water 45°, Δ T 5 °C Temp. Ambient 20 °C (UNI EN 1397:2015)
(3) Sound pressure (dBA) r=1.5m, Q=1(UNI EN ISO 3741:2010)